대한민국 자동화산업의 리더 HM TECH을 소개합니다.
. 20M sensing distance, small size 2.360 ° scanning
range,no dead ends 3.12.5HZ (Max.)scanning frequency 4.0.5 ° (Max.) resolution
Model | AS-21C | |
Light source |
Infrared laser(905nm)
|
|
Laser safety level |
Class 1 (GB7247.1-2012, Eye-safe IEC)
|
|
Laser spot light diameter |
8mm
|
|
Laser spot light scan angle |
12.5 mrad
|
|
Scanning angle range |
300°
|
|
Scanning frequency |
25Hz(system default)/12.5Hz/6.25Hz
|
|
Scanning angle resolution |
0.5°(system default)/0.25°/0.125°
|
|
Sensing range |
0.1m ~ 20m
|
|
10% reflectivity range |
15m
|
|
Outdoor performance |
Anti-dusty, Anti-sunlight
|
|
Rain fog and smoke penetration |
Supported
|
|
Measurement error | System error (typical) |
±5cm
|
Statistical error (1σ) |
±2cm
|
|
Built-in applicationRegional monitoring |
Monitoring mode: Point number monitoring / target width monitoring / contour monitoring
|
|
Monitor signal level: Attention / warning / alarm
|
||
Number of regional groups: 16 groups, support self-learning background exclusion
|
||
Concurrent work area group number: 16 (max)
|
||
Guide the network camera to monitor the target video positioning and tracking
|
||
Self-test equipment |
Contents:Transparent cover dirt / block / high temperature / low temperature Output mode: Indicator + TCP packets
|
|
Ethernet |
Rate: 10/100 Mbps; Network protocol: TCP/IP;
Function: Device configuration / measurement data output /monitor signal output
|
|
I/O Input |
Quantity:4; Type: Switching level input; High level range:10V~28V DC; Low level range:0V~5V DC
Preset function: Monitor area selection (0x0 - 0xF); Regional monitoring disarm / forced alarm, active level: high level
|
|
I/O Output |
Quantity: 4; Type: PNP switch output ; Output voltage: Supply voltage;Power on: OFF;Device ready (OUT),
active state: pass (High level), zone detection signal output (OUT2/OUT3/OUT4) active state: configurable
|
|
Indicator light |
Quantity: 2; Definition: ERR (Device alarm: Fault/Abnormal ,Transparent cover dirty / block, high and low
temperature, Dense fog); HTR (operation status indication: detection signal / self-learning )
|
|
Front panel button |
Quantity: 1; Definition: Shielded monitor signal output / start background self-learning /restart device
|
|
Operating voltage |
10V~ 28V DC
|
|
Power |
5W(measuring),3.6W@DC 12V/14.4W@DC 24V(heating)
|
|
Outer covering protection rank(IP) |
IP65(GB4208~2008)
|
|
Insulation resistance |
1MΩ(GB16796~2009.5.4.4)
|
|
Dielectric strength |
0.5KV(GB16796~2009.5.4.3)
|
|
Weight |
0.6kg
|
|
Dimension(L×W×H) |
83.5×85×104.9(mm)
|
|
Electromagnetic compatibility(EMC) | Electrostatic discharge |
6KV (GB/T17626.2~2006,class 3)
|
Fast bursts |
1KV (GB/T17626.4~2008,class 2)
|
|
Electromagnetic field radiation immunity |
GB/T17626.3~2006,class 2
|
|
Surge immunity |
GB / T17626.5-2008 Power interface: 1.2 / 50μs, 2KV / 1KA (Class 3)
Ethernet interface: 10 / 700μs, 1KV / 25A (Class 2); I / O interface: 1.5 / 50μs, 0.5KV / 0.25KA (Class 1)
|
|
Impact |
GB/T 2423.5
|
|
Single impact |
15g, 11ms
|
|
Continuous impact |
10g, 16ms
|
|
Vibration |
GB/T 2423.10
|
|
Frequency Range |
10Hz~150Hz
|
|
Amplitude |
5g
|
|
Humidity |
93%, +40℃, 2h(GB/T 2423.3)
|
|
Operating temperature range |
-25℃~+50℃
|
|
Storage temperature range |
-30℃~+70℃
|
|
Ambient illumination range |
≤70,000lux
|
|